Yes : ✔ No : ✖ Good : ●●● Fair : ●● Poor : ● |
GENERAL CONDITION |
Machine Starts and is Operable | ✔ |
S.O.S. (All Compartments) | ✖ |
VIDS/VIMS Download Available | ✖ |
GENERAL APPEARANCE |
Cleaning Required | ✔ |
Extra Fuel Tanks | ✖ |
S.O.S. Taken | ✖ |
SAFETY ITEMS |
Cab Guards | ✖ |
ROPS | ✔ |
Safety Decals In Place | ✖ |
Safety Decals Legible | ✔ |
OPERATOR STATION |
Back Up Alarm | ✔ |
Current O&MM | ✔ |
Current Parts Manual | ✖ |
Current Safety Manual | ✖ |
ROPS Certification Plate | ✖ |
ENGINE |
Blow By | ✖ |
Fuel Leaks | ✖ |
Knocking | ✖ |
Oil Leaks | ✖ |
Water in Oil | ✖ |
COOLING SYSTEM |
Water in Oil | Over flow tank cracked, has a hole in it |
ELECTRICAL, STARTING AND CHARGING SYSTEM |
Block Heater | ✖ |
Ether Aid | ✖ |
HYDRAULICS |
Ether Aid | Full and clean |
BOOM |
Boom Condition | ●●● |
Boom Pins | ●●● |
Pins & Bushings - BOOM | ●● |
STICK |
Ether Aid | 9’11”ft |
BUCKET |
Quick Coupler | ✔ |
UNDERCARRIAGE |
Quick Coupler | Cat #41-7475 |
Quick Coupler | Triple grouser pads installed |
FINAL DRIVES |
Quick Coupler | Both final drives recently replaced. |